Evaluation of Using RDFT Method for Grid Synchronisation

Authors

  • Ali H. Abduljabbar Electrical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, Iraq Author https://orcid.org/0000-0003-1367-2212
  • Saif Al-Zubaidi Electrical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, Iraq Author https://orcid.org/0000-0001-5217-5927
  • Ahmed Talib Razzooqee Electrical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, Iraq Author

DOI:

https://doi.org/10.31272/ajece.11

Abstract

The proposed work measures the accuracy of synchronization to grid using filtering technique. Where two algorithms of Recursive Discrete Fourier Transform (RDFT) are used, each one turned for a specific frequency. The algorithms are implemented using STM microcontroller. It is shown from the results, that this method can provide accurate calculations and can comply with the domestic standards of synchronisation. The need of such a method can be clear at load-side, as grid waveform can be distorted due to non-linear loads or heavy electronic loads with rectifier filter. Distorting grid with unwanted harmonics can make synchronisation difficult while using Zero Crossing Detectors (ZCD) or Phase Locked Loop (PLL). The RDFT tool, is fast and accurate method to detect waveform by filtering out undesirable perturbation. STM32F4 microcontroller was used to implemented the method and Results were obtained. The results show that using two RDFT method provides high accuracy in comparison to other.

References

M. M. Begovic, P. M. Djuric, S. Dunlap, and A. G. Phadke, “Frequency tracking in power networks in the presence of harmonics,” IEEE Transactions on Power Delivery, vol. 8, no. 2, pp. 480–486, 1993.

Yang, Bingyuan, Ke Dai, Chaowei Yang, Hui Luo, Kuan He, and Ziwei Dai. "Improvement of recursive DFT for APF with higher switching frequency to suppress wideband harmonics." IEEE Access 9 (2021): 144300-144312.

Hou, Rui, Jian Wu, Huihui Song, Yanbin Qu, and Dianguo Xu. "Applying directly modified RDFT method in active power filter for the power quality improvement of the weak power grid." Energies 13, no. 18 (2020): 4884.

Ullah, Ikram. "Synchronization of Active Power Filter under Distorted Grid Conditions." International Journal of Robotics and Control Systems 1, no. 3 (2021): 378-389.

S. Guang and Z. Xiaoming, “A fundamental wave recursive DFT algorithm applied in the inverter’s pre-synchronization,” in 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT). IEEE, 2011, pp. 544–548.

A. Al-Omari, M. Ahmed, and D. T. Bearne, “A new method for gridtie inverters synchronization based on RDFT with linear approximation,” in 2015 IEEE 11th International Conference on Power Electronics and Drive Systems. IEEE, 2015, pp. 626–629.

A. P. Martins and J. C. Ferreira, “Robust converter synchronization to a weak grid through a DFT-based method,” AP Martins, JC Ferreira// Renewable Energy & Power Quality Journal, vol. 1, no. 4, pp. 57–63, 2006.

B. P. McGrath, D. G. Holmes, and J. Galloway, “Improved power converter line synchronisation using an adaptive discrete fourier transform (DFT),” in Power Electronics Specialists Conference, 2002. pesc 02. 2002 IEEE 33rd Annual, vol. 2. IEEE, 2002, pp. 821–826.

F. Baradarani, M. Dadash Zadeh, and M. Zamani, “A phase-angle estimation method for synchronization of grid-connected power-electronic converters,” vol. 90, pp. 821–826, 2014.

H. L. Ginn and G. Chen, “Digital control method for grid-connected converters supplied with nonideal voltage,” Industrial Informatics, IEEE Transactions on, vol. 10, no. 1, pp. 127–136, 2014.

H. Ginn and G. Chen, “Reference generator for grid connected converters without direct supply synchronization,” in Industrial Electronics (ISIE), 2010 IEEE International Symposium on. IEEE, 2010, pp. 2933– 2939.

A. G. Phadke, J. S. Thorp, and M. G. Adamiak, “A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of frequency,” IEEE transactions on power apparatus and systems, no. 5, pp. 1025–1038, 1983.

H. A. Darwish and M. Fikri, “Practical considerations for recursive DFT implementation in numerical relays,” Power Delivery, IEEE Transactions on, vol. 22, no. 1, pp. 42–49, 2007.

R. Yang and H. Xue, “A novel algorithm for accurate frequency measurement using transformed consecutive points of DFT,” IEEE Transactions on Power Systems, vol. 23, no. 3, pp. 1057–1062, 2008.

Y. Xu and B. Ju, “Synchronized phasor measuring method using recursive DFT with a window function,” in 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific. IEEE, 2005, pp. 1–6.

M. J. Thompson, “Fundamentals and advancements in generator synchronizing systems,” in 2012 65th Annual Conference for Protective Relay Engineers. IEEE, 2012, pp. 203–214.

M. M. of Defence, “Defence standard 61-5 part 2 section 1,” vol. Issue3, 19th May 2006.